Tổng quan
Features
- Throughput of 60 samples per hour
- 20 parameters + 3 histograms
- 10.4 inch touch screen display
- Automatic clog clearing
- Sturdy hardware with enhanced durability
- Whole blood 12μL
- Distinct flags for quick and better diagnosis
- Memory of 35,000 sample results with histogram
- Reagent expiry alarm
- QC with L-J graph
- Intuitive software
Technology
-
Electrical Impedance/ aperture impedance/ Coulter Principle: Whole blood is passed between two electrodes through an aperture so narrow that only one cell can pass through at a time. The impedance changes as a cell passes through. The change in impedance is proportional to cell volume, resulting in a cell count and measure of volume. The Coulter principle helps in accurately determining the counts of RBCs, Platelets and WBCs as well as three differential WBC count with accurate volume distribution. This is because the change in electrical resistance of the cell passing through the small aperture in a conductive liquid depends directly on the cell volume.
-
Volumetric Metering: This analyzer uses a volumetric metering unit to control the count cycle and to ensure that a precise volume of sample is analyzed. Volumetric counting ensures accuracy of the measurements. Volumetric Board circuit is used to check the count completion time of RBC and WBC during sample test. Output of Phototransistor Fluid in-line sensor indicates if there is liquid flowing through the tubes. The Count time is calculated by measuring the time taken by the RBC/WBC fluid line to move from the sensor position located at the top to sensor position located at the bottom (WBC)/ middle (RBC). The phototransistor output voltage decreases indicating the presence of the liquid.
-
Photometry / Colorimetric Method: This is LED based technology and is used to determine Hemoglobin. The lysed WBC solution is exposed to 520 nm LED light within the WBC bath and is detected by a photodiode. Sample absorb light, when exposed to a beam of incident light. This results in reflection of a light of lower intensity. The intensity of the reflected light is inversely proportional to the concentration of the hemoglobin in the solution. The amount of absorbance of light determines the hemoglobin count.
Assay
- WBC – Number of White Blood Cells(Leukocytes)
- LYMPH# – Number of Lymphocytes
- MID# – Number of Mid Cells
- GRAN# – Number Granulocytes
- LYMPH% – Percentage of Lymphocytes
- MID% – Percentage of Mid Cells
- GRAN% – Percentage of Granulocytes
- RBC – Number of Red Blood Cells (Erythrocytes)
- HGB – Concentration of Haemoglobin
- HCT – Haematocrit(Relative volume of red blood cells)
- MCV – Mean Corpuscular Volume
- MCH – Mean Corpuscular Haemoglobin
- MCHC – Mean Corpuscular Haemoglobin Concentration
- RDW CV – Red blood cell Distribution Width Coefficient of Variation
- RDW SD – Red blood cell Distribution Width Standard Deviation
- PLT – Number of Platelets (Thrombocytes)
- MPV – Mean Platelets Volume
- PDW – Platelet Distribution Width
- PCT – Plateletcrit (Relative volume of platelets)
- PLCR – Platelet Large Cell Ratio
- WBC Histogram – White Blood Cell Histogram
- RBC Histogram – Red Blood Cell Histogram
- PLT Histogram – Platelet Histogram
WHERE TOP QUALITY IS THE FIRST PRIORITY
The Mispa Count X with Smart Impedance Technology, is an advanced 3-part differential hematology analyzer which offers quality CBC testing to deliver safe patient care.The Mispa Count X is a cost effective hematology solution tailored for different environments: routine laboratories, satellite labs, and emergency care unit. This advanced 3-part differential automated hematology analyzer brings along higher stability and minimal maintenance, which will be the ideal choice for those looking for costeffective solution at zero compromise on quality.
THE MASTER OF MATERIALS COMBINING DESIGN & HIGH-TECH TECHNOLOGY WILL STAND THE TEST OF TIME
- Throughput of 60 samples per hour
- 20 parameters + 3 histograms
- 10.4” touch screen display with 800×600 resolution
- Automatic clog clearing
- Sturdy hardware with enhanced durability
- Whole blood 14µL and Pre-diluted 20µL
- Distinct flags for quick and better diagnosis
- Memory of 35,000 sample results with histogram
- Reagent expiry alarm
- QC with L-J graph
- Intuitive software
ACCURACY GUARANTEED AT ITS BEST
Accurate and reliable Mispa Count X is a compact hematology system with 20 parameters and 3 Histograms . The Mispa Count X has a smart technology which requires only micro-sampling of 14 µL of whole blood and 20 µL of prediluted to run any mode of blood sample
PRECISION REDEFINED
High-Tech Laser cut Ruby aperture of 70 micron for RBC / PLT and 100 micron for WBC, the facets on brilliant cut gems known for its strength and high precision is designed to offer better impedance and interference free quality result.
DESIGNED FOR SPACE
Guaranteed to stand out with its classic good looks, Mispa Count X is designed to fit in any lab as it offer nsmall foot print and most ergonomic and minimalist design. Its front has an especially unique, particularly powerful design with curved sampling area which offers hazard free sampling process and provide more impressive look.Special highlight: The radial designed probe with broad aspiration switch makes sampling easy at best of convenience.
Carryover |
|||
Parameter (unit) |
Low Target
Values |
High Target
Value |
% Carryover (95% Confidence Limit) |
WBC (103/µL) |
>0 <4 |
>90 |
<1.5% |
RBC (106/µL) |
>0 <2 | >6.20 |
<1.5% |
HGB (g/dL) |
>0 <10 | >22.0 | <1.5% |
PLT (103/µL) |
>0 <100 | >900 |
<2.5% |